PC Programming PL1877A Microprocessor Radio Telephone Interconnect
12/10 22
Serial Port Setup
The PL1877A can be programmed from the Local Port or the Remote Port. This parameter must be
entered to begin programming.
If the PL1877A is installed in the same location as the computer used to program it, the serial port
selected should be Local. Refer to Input/Output - I/O Settings - Local Reading on page 24.
If the PL1877A is located at a remote location, a modem must be installed at the correct serial port.
Select Modem Port. See the Modem Installation manual for complete information.
Make sure your COMM ports are connected properly.
Input/Output – I/O Settings - Read ITI6000A
After the correct COMM port is selected, click on the Read ITI6000 tab.
N
OTE: Once Read ITI6000 begins, you will not be able to close or switch from this window until the
read either finishes or fails unless you click on Cancel.
Select Read Remote for a remote (modem) installation.
Select Read Local for a Local installation. Programming information about Read Local follows the
Remote (modem) programming information on page 24.
When the progress bar reaches 100%, click on OK. The expanded main menu is now available that
allows you to complete your IAPS programming.