Gai-tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telep Manual de usuario Pagina 132

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 172
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 131
Features PL1877A Microprocessor Radio Telephone Interconnect
12/10 126
Selective Signaling Types
DTMF
Parameter Function
1090 DTMF outpulse timing. The number of 50 ms periods in the DTMF digit/inter-digit
time. Valid range = 08.
Single Mode DTMF Paging
1131–1139
DTMF paging preamble. Valid digit range = 0$F.
2-Tone Sequential
Parameter Function
1091 2-Tone paging A tone length. The number of 0.5 second increments in duration of the
first tone of a 2-Tone sequence. Valid Range = 08 (0.5 to 4.5 seconds).
1092 2-Tone paging B tone length. The number of 0.5 second increments in duration of the
first tone of a 2-Tone sequence. Valid Range = 08 (0.5 to 4.5 seconds).
2-Tone Single Mode Paging
1129 Selected code plan # for single mode, 2-Tone paging. Valid range is 00–24 (decimal).
Determine the code plan number from the table below. Then, enter the number in this
parameter such that the 10’s digit appears in the 4 most significant bits, and the 1’s digit
appears in the 4 least significant bits. For example, for codeplan Q, enter $15
(hexadecimal 15).
General Encode Plan = 00 Modified General Encode Plan = 00
Code Plan B = 02 Code Plan N = 13
Code Plan C = 03 Code Plan P = 14
Code Plan D = 04 Code Plan Q = 15
Code Plan E = 05 Code Plan R = 16
Code Plan F = 06 Code Plan S = 17
Code Plan G = 07 Code Plan T = 18
Code Plan H = 08 Code Plan U = 19
Code Plan J = 09 Code Plan V = 20
Code Plan K = 10 Code Plan w = 21
1140-1142
Preprogrammed 2-Tone paging digits. Valid digit range = 09.