PL1877A Microprocessor Radio Telephone Interconnect Features
127 12/10
Plectron
Parameter Function
1093 Plectron paging A tone length. The number of 0.5 second increments in duration of the
first tone of a 2-tone sequence. Valid range = 08 (0.5 to 4.5 seconds).
1094 Plectron paging B tone length. The number of 0.5 second increments in duration of the
first tone of a 2-tone sequence. Valid range = 08 (0.5 to 4.5 seconds).
Plectron Single Mode Paging
1143–1146
Preprogrammed Plectron paging digits. Valid digit range = 09.
N
OTE: The first two digits of a Plectron capcode cannot exceed 35.
2805 Hz
Parameter Function
1095
The number of 10 ms periods in tone-off time for 2805 paging. Valid range = 08
(10 ms to 90 ms).
2805 Hz Single Mode Paging
1147–1155 2805 paging preamble. Valid digit range = 0–9.
1500 Hz
Parameter Function
1096
The number of 10 ms periods in tone-off time for 1500 paging. Valid range = 08
(10 ms to 90 ms).
1500 Hz Single Mode Paging
1156–1164
1500 paging preamble. Valid digit range = 09.