Gai-tronics MRTI 2000 (No. PL1877A) Microprocessor Radio Telep Manual de usuario Pagina 120

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 172
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 119
Parameter Modification PL1877A Microprocessor Radio Telephone Interconnect
12/10 114
Para-
meter
No.
Description
Control Digits
Refer to
Section on
Page:
1084 Determines the number of digits accepted
from an attendant for selective signaling.
The valid range depends on the type of
selective signaling selected.
0–6 = DTMF, 2805, 1500
0–3 = 2-Tone
0–4 = Plectron
0–6 = Motorola/EIA
123
1085 Determines the number of digits accepted
from a mobile user for selective signaling.
The valid range depends on the type
selective signaling selected.
0–6 = DTMF, 2805, 1500
0–3 = 2-Tone
0–4 = Plectron
0–6 = Motorola/EIA
123
1087 Determines the number of times to repeat
signaling.
Valid range = 0–8 122
1088 Mobile answer time - the number of 10-
second increments for a mobile to answer
a selective call before disconnection or
advancing to an alternate user ID.
Valid range = 0–15 122
1089 Landline and attendant DTMF dialing
inter-digit time - the time between digits
being entered as selective signaling input.
Valid range = 0–15 123
1090 DTMF outpulse timing - the number of 50-
ms periods in the DTMF digit/inter-digit
time.
Valid range = 0–8 126
1091 2-Tone paging A tone length - the number
of .5-second increments in the duration of
the first tone of a 2-Tone sequence.
Valid range = 0–8 126
1092 2-Tone paging B tone length - the number
of .5-second increments in the duration of
the second tone of a 2-Tone sequence.
Valid range = 0–8 126
1093 Plectron paging A tone length - the number
of .5-second increments in the duration of
the first tone of a Plectron tone sequence.
Valid range = 0–8
(.5 to 4.5 seconds)
121
1094 Plectron paging B tone length - the number
of .5 second increments in the duration of
the second tone of a Plectron tone
sequence.
Valid range = 0–8
(.5 to 4.5 seconds)
121
1095 2805 Tone off time - the number of 10-ms
periods in tone off time for 2805 paging.
This parameter is x in the following
equation: 10 ms + x (10 ms).
Valid range = 0–8
(10–90 ms)
127
1096 1500 Tone off time - the number of 10 ms
periods in tone off time for 1500 paging.
Valid range = 0–8
(10–90 ms)
127