IP Module Command Line Syntax
Action
Verb
Parameters
Comment
1 2 3
SET
DHCP [ON/OFF]
Enables or disables the use of DHCP for the
assignment of IP parameters.
ADDRESS xxx.xxx.xxx.xxx Sets the static IP Address of this unit
MASK xxx.xxx.xxx.xxx Sets the static sub-net mask for this unit
GATEWAY xxx.xxx.xxx.xxx Sets the static default gateway address for this unit
DNS1 xxx.xxx.xxx.xxx Sets the IP address of the primary static DNS server.
DNS2 xxx.xxx.xxx.xxx
Sets the IP address of the secondary static DNS
server.
WEBPORT
XXXX
The TCP port through which the Telephone Web
server can be accessed (Default Value is 80)
WEB [ON/OFF]
This command enables or disables access to the web
server (Default value is ON )
TELNETPORT XX
The TCP port through which the Telephones telnet
server can be accessed (Default Value is 23)
TELNET [ON/OFF]
This command enables or disables access to the
telnet server (Default value is ON )
SYSLOGPORT xx
This command sets the port number to be used for
syslog messages. The default value is 514
SYSLOG
xxx.xxx.xxx.xxx
or
FQDN
This command sets the destination address for syslog
server messages.
SYSLOGPORT2 xx
This command sets the port number to be used for
syslog messages (second syslog server). The default
value is 514
SYSLOG2
xxx.xxx.xxx.xxx
or
FQDN
This command sets the destination address for syslog
server messages (second syslog server).
SYSLOGFACILIT
Y
xx
The SYSLOG message facility level, as per RFC3164.
SYSLOGSEVERI
TY
The SYSLOG message severity level, as per
RFC3164.
STUN
xxx.xxx.xxx.xxx
or
FQDN
This command sets the IP address or URL for the
STUN server that will be used to resolve STUN
requests. The absence of parameter 2 will disable the
STUN facility.
SHOW ALL
Lists all the configuration settings for the IP Module.
The current static settings will be displayed along with
the current settings if the unit is using a Dynamic IP
address
PING
xxx.xxx.xxx.xxx
or
FQDN
Sends an ICMP ping to the IP address or the FQDN
given in parameter 1
TRACER
OUTE
xxx.xxx.xxx.xxx
or
FQDN
Executes a series of PING messages with varying
HOP numbers in order to determine the routing used
to reach the destination address.
9.12 LOCAL Module Command Line Syntax
Action
Verb
Parameters
Comment
1 2
SET
SPEED
9600 Sets the Port speed to be 9.6 Kbps (Default)
19200 Sets the Port speed to be 19.2 Kbps
38400 Sets the Port speed to be 38.4 Kbps
57600 Sets the Port speed to be 57.6 Kbps
115200 Sets the Port speed to be 115.2 Kbps
SHOW ALL