L3149B (C200) Advanced Tone Remote Desk Set Installation
35
Level Adjustments and Diagnostics
The programming buttons, PROG 1/5 through PROG 4/8, are used to navigate the menu for specific
installations and to perform diagnostics. They are:
Line Output Level
Line In Sensitivity
Diagnostics
Tone Level Adjustments
The diagram below illustrates which buttons to press to access the programming features.
Press: To program:
PROG 1/5
Line Output Adjust Default: -10 dB
PROG 2/6
Line Input Sensitivity Default: -9 dB
PROG 3/7
Internal Diagnostics:
Press: To program:
PROG 2/6
DC Module Diagnostic:
Press: To program:
LOCK + PROG 1/5 DCLOTL Threshold
LOCK + PROG 4/8 DCLOTL Threshold with no dc
supply
PROG 1/5
Relay Module Diagnostic
PROG 3/7
RS232 Diagnostic
PROG 4/8
Keyboard Diagnostic
PROG 4/8
Tone Level Adjust
Press: To program:
PROG
1/5
Sidetone Level Adjust Default: 0 dBm
PROG 2/6
Alert Tone Level Adjust Default: 0 dBm
PROG 3/7
Page Level Adjust Default: 0 dBm
Comentarios a estos manuales