Connectors
• Plug P1 connects the integrated microphone to the RF Call Box PCBA in Models CB193-xxx and
CB195-xxx.
•
Plug P2 connects the RF Module or 190-3170K Kit cable to the RF Call Box PCBA. Pin-out
information for P2 is as follows:
Models
CB19x-001 and CB19x-002
Model CB19x-003 with
190-3170K Adapter Kit
Pin Number Function Pin Number Function
1 - 1 -
2 - 2 -
3 - 3 -
4 - 4 -
5 Power Level 5 -
6 Power 6 Power
7 Audio TX 7 Audio TX
8 - 8 -
9 - 9 -
10 - 10 -
11 Tone Detect 11 Tone Detect
12 Audio RX 12 Audio RX
13 Carrier Detect 13 Carrier Detect
14 PTT 14 PTT
15 Ground 15 Ground
• Plug P3 connects the speaker to the RF Call Box PCBA in Models CB193-xxx and CB195-xxx.
•
Terminal Strip TB1 connects the RF Call Box PCBA to its power source.
• Plug P6 connects the push-to-talk switch to the RF Call Box PCBA in Models CB193-xxx and
CB195-xxx.
• Programming Jack
J1 connects the PCBA to the computer for configuring the module for customer
specific operation using the CARD Suite Software application and the XAC0004A programming
cable.