Gai-tronics 400-003 IEC / ATEX Zone 1 RigCom Station Manual de usuario

Busca en linea o descarga Manual de usuario para Comunicación Gai-tronics 400-003 IEC / ATEX Zone 1 RigCom Station. GAI-Tronics 400-003 IEC / ATEX Zone 1 RigCom Station User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 17
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Pub. 42004-460A
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model 400-003 IEC/ATEX
Zone 1 RigCom Station
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
GAI-Tronics Model 400-003 IEC/ATEX Zone 1 RigCom Station is designed for common-talk, or
master/slave communication system operation in IEC Zone 1 hazardous locations.
The unit provides push-to-talk, release-to-listen operation, and has a local on/off volume control switch to
activate and control the volume level for each station independently.
Model 400-003 has three M20 threaded entry holes for system, power, loudspeaker and optional remote
microphone and footswitch connection.
The Model 400-003 is designed to operate with other 400-003 stations, and GAI-Tronics EZ Page Series
of non-hazardous area rated equipment.
Figure 1. Model 400-003 RigCom Station
Vista de pagina 0
1 2 3 4 5 6 ... 16 17

Indice de contenidos

Pagina 1 - Zone 1 RigCom Station

Pub. 42004-460A GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA 610-777-1374  800-492-1212  Fax: 610-796-5954 VISIT WW

Pagina 2 - Installation

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 10 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 0

Pagina 3 - Mounting

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 11 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 0

Pagina 4 - Hardware Configuration

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 12 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 0

Pagina 5

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 13 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 0

Pagina 6

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 14 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 0

Pagina 7

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 15 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 0

Pagina 8

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 16 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 0

Pagina 9 - Field Installation Interface

(Rev. 10/06)WarrantyEquipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that anyGAI-Tronics equipment supplied her

Pagina 10 - Name Pin No. Description

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 2 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 09

Pagina 11

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 3 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 09

Pagina 12 - Operation

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 4 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 09

Pagina 13 - Master/Slave System

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 5 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 09

Pagina 14 - Maintenance

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 6 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 09

Pagina 15 - Specifications

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 7 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 09

Pagina 16 - Approvals

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 8 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 09

Pagina 17 - Return Policy

Pub. 42004-460A Model 400-003 IEC/ATEX Zone 1 RigCom Station Page: 9 of 16 f:\standard ioms - current release\42004 instr. manuals\42004-460a.doc 09

Comentarios a estos manuales

Sin comentarios